Therequirements of Industrial washing machine for inverters:

1. VFD could provide high torque,multi-speed, wide voltage range, automatic slip compensation and convenientcommunication mode; with stable performance, VFD could adapt to high temperatureand high humidity environment in various hotels laundry rooms;

2. VFD could adapt to the specific washingprocess requirements of industrial washing machines and service requirementsfor specific customer

groups.

Wiring:

1. V / F curve user-defined of VFD is themost critical step in industrial washing machine application's   debugging, the debugging process must beoptimized according to the site conditions.

The main principles:

1.the start of Industrial washingmachine should be slow and steady, the inverter's low-frequency starting torqueshould be large.

2. Please note the V / F curve slope, if eachV/F curve set point slope is too large, it will cause the running current istoo large. Or if the slope is too small, it will be too small to start.Therefore, it should be define   accordingto the motor and its scene.

Attached: because of the special processrequirements for the automatic industrial washing machine,   generally,we will increase one or two power levelof the inverter for washing machine, base on the its motor rated power.


Parameters setting:


Code

Name

Setting

Description

Remark

b0-01

Control mode

2

V/F control

Factory default

b0-02

Command source

1

External terminal control


b0-03

Main frequency source X selection

6

Multi-speed function


b0-13

Maximum frequency

120HZ

Tuning according to the real requirement


b0-15

Frequency upper limit

120HZ

b0-21

Acceleration time

120s

b0-22

Deceleration time

120S

b2-03

Acceleration time 2

40S

b2-04

Deceleration time 2

40S

b2-13

Acceleration time 1 and time 2   switching frequency point

25.00HZ


Run b2-03/b2-04 below   25HZRun b0-21/b0-22 above 25HZ

b2-14

deceleration time 1 and time 2   switching frequency point

25.00HZ

b3-00

DI1 function selection

1

forward

Factory default

b3-01

DI2 function selection

2

reverse

b3-02

DI3 function selection

6

multi-function 1

b3-03

DI4 function selection

7

multi-function 2

b3-04

DI5 function selection

8

multi-function 3

C1-00

multi-function 0

6.25%

7.5HZ

Washing

C1-01

multi-function 1

16.67%

20HZ

Equipartition

C1-02

multi-function 2

66.67%

80HZ

Medium anhydration

C1-04

multi-function 3

100%

120HZ

Heavy anhydration

C1-00C1-07 will be   changing as different applications, When testing the machine, it needs to be   adjusted according to the actual situation.

d0-00d0-04

Should be set according to   motor’s nameplate

d2-00

V/F curve setting

1

Multi point V/F curve


d2-07

V/F frequency point3

50.00HZ

Multi point V/F curve setting


d2-08

V/F voltage point3

100.0%

d2-05

V/F frequency point2

25.00HZ

d2-06

V/F voltage point2

60.0%

d2-03

V/F frequency point1

8.00HZ

Improve low   frequency torque,tuning d2-03 according to the real current during washing process

d2-04

V/F voltage point1

30.0%

Notes: normally, the washing current will not overthan 28A for 7.5KW washing machine. If it was over than 28A, V/F curve may beset inreasonable or wrongly motor parameters.